Compliant storage and rental solutions for Propionic Anhydride (C6H10O3). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Propionic Anhydride is a colorless liquid with a very strong, unpleasant odor. It is used in the manufacture of perfumes, oils, resins, dyestuffs, drugs, and cellulose esters.
Flammable liquids (Category 4), H227 Skin corrosion (Category 1B), H314 Serious eye damage (Category 1), H318 For the full text of the H-Statements mentioned in this Section, see Section 16.
Dry Chemical fire suppression is recommended for Propionic Anhydride
Guidance: Dry Chemical fire suppression is generally recommended for Propionic Anhydride (C6H10O3). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.Water Foam Carbon dioxide (CO2) Dry powder
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Propionic Anhydride should account for its listed hazards, climate control needs (below +30°C.), and segregation requirements. Propionic Anhydride is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); REDUCING AGENTS; ALCOHOLS;
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Melting point/freezing point Melting point/range: -43 °C (-45 °F) - lit. f) Initial boiling point and boiling range 167 °C 333 °F - lit. g) Flash point 74 °C (165 °F) - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits Upper explosion limit: 11.9 %(V) Lower explosion limit: 1.48 %(V) k) Vapor pressure 13 hPa at 57.7 °C (135.9 °F) l) Vapor density 4.49 - (Air = 1.0) m) Density 1.015 g/cm3 at 25 °C (77 °F) - lit.
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Propionic Anhydride in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: below +30°C.. Compatibility notes: Propionic Anhydride is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); REDUCING AGENTS; ALCOHOLS; US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Propionic Anhydride is flagged as a flammable hazard in this database (Yes). Flash point: 74 °C (165 °F) - closed cup. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Propionic Anhydride is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 4), H227 Skin corrosion (Category 1B), H314 Serious eye damage (Category 1), H318 For the full text of the H-Statements mentioned in this Section, see Section 16.
Dry Chemical fire suppression is generally recommended for Propionic Anhydride (C6H10O3). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Propionic Anhydride. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.